| CHP
Performance |
|
|
|
ASE
8
|
ASE
40
|
ASE
50
|
|
Output |
kW |
506 |
3,028 |
3,482 |
| Fuel
Flow |
lb/h
|
397 |
1,916 |
2,033 |
|
kg/h
|
180 |
871 |
924 |
|
Fuel Flow |
MM Btu/kWh |
8.2 |
39.4 |
41.8 |
|
106 kJ/kWh |
8.7 |
41.5 |
44.1 |
| Heat
Rate |
Btu/kWh
(LHV) |
16,122 |
12,999 |
12,001 |
|
kJ/kWh
(LHV) |
17,008 |
13,711 |
12,659 |
|
Efficiency |
% |
21.2 |
26.3 |
28.4 |
| Exhaust
Flow |
lb/s |
7.9 |
28.1 |
30.9 |
|
kg/s |
3.6 |
12.8 |
14.0 |
|
Exhaust Temperature |
oF |
916 |
1,118 |
1,053 |
|
oC |
491 |
603 |
567 |
| Nominal
Fuel Gas Pressure |
psig |
200 |
|
kg/cm2 |
14.06 |
| Steam
Generation |
| |
|
ASE
8
|
ASE
40
|
ASE
50
|
|
Unfired |
lb/h |
4,500 |
21,700 |
22,200 |
|
kg/h |
2,045 |
9,864 |
10,091 |
| Fired
to 1,600o |
lb/h |
10,000 |
35,000 |
40,000 |
|
kg/h |
4,545 |
15,909 |
18,182 |
|
Duct Burner Fuel Flow |
MMBtu/h (LHV) |
5.4 |
13.5 |
18.1 |
|
106 kJ/h (LHV) |
5.7 |
14.2 |
19.1 |
| Fired
to 2,200oF |
lb/h |
16,000 |
60,000 |
65,000 |
|
kg/h |
7,273 |
27,273 |
29,545 |
|
Duct Burner Fuel Flow |
MMBtu/h (LHV) |
11.5 |
39.0 |
43.5 |
|
106 kJ/h (LHV) |
12.1 |
41.1 |
45.9 |
| Fully
Fired |
lb/h |
|
80,000 |
85,000 |
|
kg/h |
|
36,364 |
36,636 |
|
MMBtu/h
(LHV) |
|
59.5 |
64.1 |
|
106
kJ/h (LHV) |
|
62.8 |
67.6 |
Notes:
| ISO Conditions |
Steam Conditions 59F
(15C), Sea Level, 60% Relative Humidity |
| Duct
Losses, Simple Cycle |
Inlet - 0" (0
mm) H2 Exhaust - 0" (0 mm) H20 |
| Duct Losses, CHP Cycle |
Inlet - 3" (76.2
mm) H20 Exhaust - 10" (250 mm) H20 |
| Generator |
60 Hz, 4160V (480V
for ASE8) |
Fuel Heating Value
(LHV) Natural Gas Distillate Oil |
20,548 Btu/lb (47,786 kJ/kg) 18,300 Btu/lb (42,558 kJ/kg) |
| Steam Conditions |
150 psig (1034 kPa),
Saturated |
| Mechanical Efficiency |
95% |
|