VPS Series Gensets
|
 |
| Simple Cycle Performance* |
| |
|
VPS1
|
VPS3
|
VPS4
|
|
Output Power |
kW |
487 |
3,086 |
3,451 |
| Heat
Rate |
Btu/kWh |
16,754 |
12,704 |
12,047 |
|
KJ/kWh |
17,676 |
13,403 |
12,709 |
|
Thermal Efficiency |
(%) |
20.4 |
26.9 |
28.3 |
| Fuel
Flow |
lb/h |
397 |
1,908 |
2,023 |
|
kg/h |
180 |
865 |
917 |
|
Heating Value (LHV) |
Btu/lb |
20,548 |
20,548 |
20,548 |
|
KJ/kg |
47,786 |
47,786 |
47,786 |
| Fuel
Pressure Required (min/max) |
Psig |
250/300 |
200/250 |
250/300 |
|
KPA |
1,723/2,068 |
1,379/1,723 |
1,723/2,068 |
|
Exhaust Gas Flow |
lb/s |
7.8 |
28.0 |
30.2 |
|
kg/s |
3.56 |
12.7 |
13.7 |
| Exhaust
Gas Temperature |
F |
913 |
1,114 |
1,081 |
|
C |
489 |
601 |
583 |
|
Length (A) |
ft |
14.0 |
25.3 |
25.3 |
|
m |
4.27 |
7.72 |
7.72 |
| Width
(B) |
ft |
14.1 |
20.0 |
20.0 |
|
m |
4.29 |
6.10 |
6.10 |
|
Height (C) |
ft |
8.5 |
8 .6 |
8.6 |
|
m |
2.59 |
2.64 |
2.64 |
*Nominal Performance -
59 F, Sea Level, RH 60%, 3”/4” losses, gear and generator
losses included; operating on Natural Gas
VPS Series Scope of Supply
Standard Equipment
- ASE Series Gas Turbine
- Reduction Gear Box
- Generator (Synchronous, 50Hz/60Hz),
WPII
- Natural Gas Fuel System
- Lube System (water cooled)
- Electro Hydraulic Start System
- Structural Steel Base, Weatherproof
Acoustic Enclosure (Gas Turbine,
- Reduction Gearbox) with Ventilation
Air System
- Combustion Air Intake System
(Barrier Filter)
- Allen Bradley PLC
- Exhaust Gas Diffuser and Expansion
Metal Bellows
Optional Equipment
- Gas Turbine Water Wash System
- Open Ventilated and Totally Enclosed
Water-to-Air Cooled
- (TEWAC) Enclosures, 50 Hz, other
Voltages, High Voltage
- Generator Switchgear
- Distillate Fuel System, Dual
Fuel System, Fuel Gas Conditioning
- Skid, Fuel Gas Compressor, Water
Injection System
- Oil/Air Cooler
- Black Start System
- No Enclosure, No Fire and Combustible
Gas Detection or
- Suppression Systems
- Self Cleaning Filter, Chilling,
Evaporative Cooling
- Generator Controls, MCC, HMI-Station,
Uninterruptible Power
- Supply (UPS), Control Room Building,
Remote Control Interfaces
- Exhaust Silencer, Stack, Heat
Recovery Steam Generator (20,000 - 65,000 lb/h)
|
 |
| |
|
 |
|