VPS Series Gensets

Simple Cycle Performance*
    VPS1 VPS3 VPS4
Output Power kW 487 3,086 3,451
Heat Rate Btu/kWh 16,751 12,716 12,205
  KJ/kWh 17,671 13,415 12,686
Thermal Efficiency (%) 20.4 26.8 28.4
Fuel Flow lb/h 397 1,910 2,020
  kg/h 180 866 916
Heating Value (LHV) Btu/lb 20,548 20,548 20,548
  KJ/kg 47,786 47,786 47,786
Fuel Pressure Required (min/max) Psig 250/300 200/250 250/300
  KPA 1,723/2,068 1,379/1,723 1,723/2,068
Exhaust Gas Flow lb/s 7.8 28.0 30.1
  kg/s 3.5 12.7 13.7
Exhaust Gas Temperature F 913 1,115 1,080
  C 489 602 582
Length (A) ft 14.0 25.3 25.3
  m 4.27 7.72 7.72
Width (B) ft 14.1 20.0 20.0
  m 4.29 6.10 6.10
Height (C) ft 8.5 8 .6 8.6
  m 2.59 2.64 2.64

*Nominal Performance - 59 F, Sea Level, RH 60%, 3"/4" losses, gear and generator losses included; operating on Natural Gas

VPS Series Scope of Supply

Standard Equipment

  • ASE Series Gas Turbine
  • Reduction Gear Box
  • Generator (Synchronous, 50Hz/60Hz), WPII
  • Natural Gas Fuel System
  • Lube System (water cooled)
  • Electro Hydraulic Start System
  • Structural Steel Base, Weatherproof Acoustic Enclosure (Gas Turbine,
  • Reduction Gearbox) with Ventilation Air System
  • Combustion Air Intake System (Barrier Filter)
  • Allen Bradley PLC
  • Exhaust Gas Diffuser and Expansion Metal Bellows

Optional Equipment

  • Gas Turbine Water Wash System
  • Open Ventilated and Totally Enclosed Water-to-Air Cooled
  • (TEWAC) Enclosures, 50 Hz, other Voltages, High Voltage
  • Generator Switchgear
  • Distillate Fuel System, Dual Fuel System, Fuel Gas Conditioning
  • Skid, Fuel Gas Compressor, Water Injection System
  • Oil/Air Cooler
  • Black Start System
  • No Enclosure, No Fire and Combustible Gas Detection or
  • Suppression Systems
  • Self Cleaning Filter, Chilling, Evaporative Cooling
  • Generator Controls, MCC, HMI-Station, Uninterruptible Power
  • Supply (UPS), Control Room Building, Remote Control Interfaces
  • Exhaust Silencer, Stack, Heat Recovery Steam Generator (20,000 - 65,000 lb/h)